What is Raid
Raid Stand for Redundant Array of Independent Disks,Data is distributed across the drives in one of several ways, referred to as RAID levels, depending on the required level of redundancy and performance.Redundant Array of Inexpensive Disks is a data storage virtualization technology that combines multiple physical disk drive components into one or more logical units for the purposes of data redundancy, performance improvement, or both.Each schema, or RAID level, provides a different balance among the key goals: reliability, availability, performance, and capacity. RAID levels greater than RAID 0 provide protection against unrecoverable sector read errors, as well as against failures of whole physical drives.
RAID 0
RAID 0 consists of striping, but no mirroring or parity. Compared to a spanned volume, the capacity of a RAID 0 volume is the same; it is sum of the capacities of the disks in the set. But because striping distributes the contents of each file among all disks in the set, the failure of any disk causes all files, the entire RAID 0 volume, to be lost. A broken spanned volume at least preserves the files on the unfailing disks. The benefit of RAID 0 is that the throughput of read and write operations to any file is multiplied by the number of disks because, unlike spanned volumes, reads and writes are done concurrently,and the cost is complete vulnerability to drive failures.
RAID 1
RAID 1 consists of data mirroring, without parity or striping. Data is written identically to two drives, thereby producing a "mirrored set" of drives. Thus, any read request can be serviced by any drive in the set. If a request is broadcast to every drive in the set, it can be serviced by the drive that accesses the data first (depending on its seek time and rotational latency), improving performance. Sustained read throughput, if the controller or software is optimized for it, approaches the sum of throughputs of every drive in the set, just as for RAID 0. Actual read throughput of most RAID 1 implementations is slower than the fastest drive. Write throughput is always slower because every drive must be updated, and the slowest drive limits the write performance. The array continues to operate as long as at least one drive is functioning.
RAID 2
RAID 2 consists of bit-level striping with dedicated Hamming-code parity. All disk spindle rotation is synchronized and data is striped such that each sequential bit is on a different drive. Hamming-code parity is calculated across corresponding bits and stored on at least one parity drive.[11] This level is of historical significance only; although it was used on some early machines (for example, the Thinking Machines CM-2) as of 2014 it is not used by any commercially available system
RAID 3
RAID 3 consists of byte-level striping with dedicated parity. All disk spindle rotation is synchronized and data is striped such that each sequential byte is on a different drive. Parity is calculated across corresponding bytes and stored on a dedicated parity drive. Although implementations exist, RAID 3 is not commonly used in practice.
RAID 4
RAID 4 consists of block-level striping with dedicated parity. This level was previously used by NetApp, but has now been largely replaced by a proprietary implementation of RAID 4 with two parity disks, called RAID-DP. The main advantage of RAID 4 over RAID 2 and 3 is I/O parallelism: in RAID 2 and 3, a single read I/O operation requires reading the whole group of data drives, while in RAID 4 one I/O read operation does not have to spread across all data drives. As a result, more I/O operations can be executed in parallel, improving the performance of small transfers.
RAID 5
RAID 5 consists of block-level striping with distributed parity. Unlike RAID 4, parity information is distributed among the drives, requiring all drives but one to be present to operate. Upon failure of a single drive, subsequent reads can be calculated from the distributed parity such that no data is lost. RAID 5 requires at least three disks.Like all single-parity concepts, large RAID 5 implementations are susceptible to system failures because of trends regarding array rebuild time and the chance of drive failure during rebuild (see "Increasing rebuild time and failure probability" section, below). Rebuilding an array requires reading all data from all disks, opening a chance for a second drive failure and the loss of the entire array. In August 2012, Dell posted an advisory against the use of RAID 5 in any configuration on Dell EqualLogic arrays and RAID 50 with "Class 2 7200 RPM drives of 1 TB and higher capacity" for business-critical data.
RAID 6
RAID 6 consists of block-level striping with double distributed parity. Double parity provides fault tolerance up to two failed drives. This makes larger RAID groups more practical, especially for high-availability systems, as large-capacity drives take longer to restore. RAID 6 requires a minimum of four disks. As with RAID 5, a single drive failure results in reduced performance of the entire array until the failed drive has been replaced. With a RAID 6 array, using drives from multiple sources and manufacturers, it is possible to mitigate most of the problems associated with RAID 5. The larger the drive capacities and the larger the array size, the more important it becomes to choose RAID 6 instead of RAID 5. RAID 10 also minimizes these problems
How to configure RAID?
1>Open Windows Server 20122>Open Dashboard3>Select Tools
4>Select Computer management
5>Select Disc Management
6>Select Disc
7>Right Click on Disc
8>Select New Raid volume as you need
9>Add 3 Hard Disk- next
10>Give it Drive letter
11>Format with NTFS FIle System.
12> Next upto finish
Conclusion
No comments: